Method

This page names every formula the site uses, says how numbers are rounded, describes the competition data behind the standards and lists what we never claim.

Formulas we use

One rep max formulas
FormulaEstimated maxBest rep range
Brzyckiw × 36 ÷ (37 − r)2 to 10
Epleyw × (1 + r ÷ 30)2 to 10
Landerw ÷ (1.013 − 0.0267123 r)2 to 10
Lombardiw × r^0.102 to 10
Mayheww ÷ (0.522 + 0.419 × e^(−0.055 r))2 to 10
O'Connerw × (1 + 0.025 r)2 to 10
Wathanw ÷ (0.488 + 0.538 × e^(−0.075 r))2 to 10

w = weight lifted. r = reps completed. One rep returns the weight lifted. Estimates are most useful at 2 to 10 reps and can be off by 10% or more.

Last reviewed

One rep max

A one rep max calculator estimates the most weight you could lift once, based on a set of several reps. The site uses seven well-known formulas: Epley, Brzycki, Lombardi, Mayhew, O'Conner, Wathan and Lander.

The headline number is the middle of the seven estimates. The tool also shows the lowest and the highest, so you can see the spread. If you enter one rep, the result is the weight you lifted, because a single is already a max for that day.

Formulas drift as reps climb. Above about 10 reps the estimates spread out and become less useful. Estimates can be off by 10% or more, even in the best case.

Percent tables and reverse weights

Percentage tables and "what weight for this many reps" results use the same formulas. They take your one rep max and work out the load for a given number of reps, or the share of your max a given set represents.

Weights round half up to the step you choose, such as 5 lb or 2.5 kg.

Scores

DOTS, Wilks, Wilks (2020 update) and IPF GL Points all turn a total and a bodyweight into one score, so lifters of different sizes can be compared.

  • DOTS is a bodyweight-adjusted score for a powerlifting total.
  • Wilks is the older formula.
  • Wilks (2020 update) is the revised version of Wilks.
  • IPF GL Points uses the coefficients from the IPF May 2020 table, valid as published to 31 December 2023. We checked on 27 November 2026 and found no newer table. The IPF formula gives zero for men under 40 kg and women under 35 kg.

Scores are for comparing lifters. They do not say how strong anyone is in absolute terms.

RPE

The RPE chart is a widely used community copy of a chart attributed to Mike Tuchscherer. It covers reps 1 to 12. Four cells beyond the published range are extended by us and marked as such on the chart.

The chart is a guide, not a test. Rating effort takes practice, and two lifters can rate the same set differently.

5/3/1

The 5/3/1 calculator uses weekly percentages of a training max. The training max is 85% of your one rep max by default, with 90% as an option, or you can type your own number. A deload week is a common option, not a rule of the program. The site is not affiliated with Jim Wendler.

Plates, bars, warm-ups and attempts

Plate loading follows the IPF loading order, with the heaviest plates loaded innermost and lighter plates outward. If your plate set cannot make the exact weight, the tool shows the closest load.

The warm-up ladder and the attempt percentages are our design, based on common coaching guidance. They are not rules from any federation.

Sources

We compile information from published research, federation rulebooks, coach protocols, manufacturer documentation and public competition data from OpenPowerlifting.

The standards use a plain "built from OpenPowerlifting data" note on each page.

Rounding

Display rounding is always half up on the number as written. Estimates show one decimal place. Standards show whole numbers. Weights in tables round to the step shown in the table. Rounding is for display only.

Data we use

The standards are built from OpenPowerlifting data. The data set is the 21 November 2026 release, and the date is shown on each page. We keep these rules.

  • Competition lifters only. Everyone in the data entered a powerlifting meet. The standards do not describe the general public.
  • Raw lifts only. Lifters in wraps and equipped categories are left out.
  • All federations. Drug-tested and untested federations are combined.
  • One best value per lifter. Each lifter counts once per table cell.
  • Level names are percentile cut-offs. Beginner is the 10th percentile, novice the 30th, intermediate the 50th, advanced the 75th and elite the 95th.
  • Small groups are hidden. A table cell with fewer than 100 lifters is not shown.

Standards show whole kilograms and pounds, whole percentiles and ratios to two decimals. Shares in the 1000 lb club page show one decimal place.

What we never claim

  • That an estimate is your true max. It is a calculation, not a tested lift.
  • That any result is medical advice, or a prescription for your training.
  • That any federation, coach or program endorses this site.
  • That standards describe anyone other than competition lifters.

How we keep it current

We plan to review the site every six months, and again whenever a federation changes a rule that the site uses. Each page shows the date it was last reviewed.

If you find a mistake, tell us through the contact page. Include the page, the numbers you entered and the result you expected.

Questions

Which one rep max formula does the site use?

It uses seven: Epley, Brzycki, Lombardi, Mayhew, O'Conner, Wathan and Lander. The headline estimate is the middle value of the seven. If you enter one rep, the result is the weight you lifted.

How accurate are the estimates?

Estimates can be off by 10% or more, and they drift further above about 10 reps. Treat an estimate as a planning number, not as your tested max.

Where does the standards data come from?

It comes from OpenPowerlifting, a public database of meet results. We use the 21 November 2026 release, competition lifters only, raw lifts, one best value per lifter.

How do I report an error?

Use the contact page. Include the page, the numbers you entered and the result you expected.